Link-systems OmniLink - PLC Interface Bedienungsanleitung Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 53
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
June 5, 2000 Man ual Rev 1 .0 5.12
Value:
Standard Numeric
Meaning:
Non-Zero if Clutch is engaged. This basically tells the PLC when the press is actually stroking.
Section 5.7.24 Parameter 024 - Crankshaft Direction of Rotation
Value:
Standard Numeric
Meaning:
0 for forward rotation. Non-Zero for reverse rotation.
Section 5.7.25 Parameter 025 - Stop Time Limit (Top)
Value:
Standard Numeric
Meaning:
The stopping time limit of the press in milliseconds for stops at the top of the stroke. See Press
Control Manual for more information.
Section 5.7.26 Parameter 026 - Stop Time Limit (Not at Top)
Value:
Standard Numeric
Meaning:
The stopping time limit of the press in milliseconds for stops NOT at the top of the stroke.
Section 5.7.27 Parameter 027 - Start Time Limit
Value:
Standard Numeric
Meaning:
The starting time limit of the press in milliseconds.
Section 5.7.28 Parameter 028 - Last Stop Time
Seitenansicht 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 52 53

Kommentare zu diesen Handbüchern

Keine Kommentare